INTELLIGENT GENERATOR, CHANGE
OVER & POWER LIMITER – THREE PHASE & SINGLE PHASE
A fully intelligent highly reliable electronic system for efficient distribution of individually predecided preset Generator power in an Electrical installation of High Rise Apartments, Flats, Group Housing complexes and township, commercial Malls, offices etc.
Load an Generator power supply in Factory settable as per customer requirement Single phase and three phase models with different capacities are available. These are being extensively incorporated in prestigious projects by eminent Electrical Consultants, Architects, Builders etc. This device is brought to you by “NEOWATTS TECHNOCRAFTS”.
INTELLIGENT GENERATOR CHANGE OVER & POWER LIMITER (IGC)
OPERATIONS
- (1) Normally when the mains supply is available, the IGC allows metered unrestricted Supply from mains.
- (2) When the mains supply fails and stand by Generator Power Supply is On, IGC connects the generator power (normally un-metered) to each Flat/Office/Villa/Shop in a sequence, monitoring load.
- (3) The generator power allotment is Factory set and sealed in IGC as per buyer specification and is available on all load circuits.
- (4) Whenever the load current exceeds preset limit, the generator power is automatically switched off for 15 seconds necessitating the user to reduce the load to allotted power and then automatically restore it.
- (5) This Function repeats till over load exists on resumption of mains power it again automatically change over.
ADVANTAGES
- (1) Fully automatic and intelligent system, replacing outdated manual system.
- (2) No separate wiring required full load can be connected to generator power.
- (3) Allotted power is assured. More power cannot be consumed on generator running.
- (4) Avoid Generator over loading by setting maximum load and precision monitoring.
- (5) Significant saving on wall space and wiring. Total cable saving for entire complex.
- (6) Fully solid state with LED indication of all operational status.
- (7) Wide range of single phase and the three phase models.
- (8) Type tested by STIC.
Notes
- (1) The circuit breaker monitors load current only, ignoring power factor. Hence there may be an apparent discrepancy in equating amperes with especially at lower power factor.
- (2) Model IGC 001 is suitable only for lighting lads and is not recommended for air conditioning load.
- (3) All models have a common “Neutral” unless specified otherwise.
- (4) It is available to connect the ELCB, if any at the load outgoing side of a changeover.
MODEL | CAPACITY | TRIP CURRENT RANGE(Factory setup sealed) | PRODUCT APPLICATION |
1GC 001 | MAX 304 lighting load | 1A to 20A Single phase Input | Lighting load |
1 GC 003 | 32 A per phase 3 phase | 5A to 25A per phase 3phase input | 3 phase lighting at A/C load |
1 GC 453 | 45A per phase 3 phase | 10A to 40A per phase 3 phase input | 3 phase lighting at A/C load |
1 GC 703 | 70A per phase 3 phase | 10A to 60A per phase 3 phase input | 3 phase lighting at A/C load |