Specifications

Electrolyte level indicator cells equipped with easy to read electrolyte level indicator

Slider 2

Specifications

Corrosion-resistant and heavy duty positive grids to enhance cyclic life

Slider 3

Specifications

Defect free fine grained tough spines to give long life to battery

Slider 4

Specifications

Low antimony alloy minimizes water loss and reduces topping up frequency

Slider 5

Specifications

World class PE separators used for low internal resistance

Congratulation on selecting digital signal processor based sinewave external battery UPS joining the family of the lakhs of satisfied uses of "NEOWATTS TECHNOCRAFTS" products. Before using this UPS please read the manual carefully to familiaize yourself with all its features, controls, safety precautions.
ENJOY UNINTERRUPTED Power!

LDC Indications
  • (a)  Battery Voltage -
    12V 24V 36V 48V
    Charging cut off 14.4 VDC 28.8 VDC 43.2 VDC 57.6 VDC
    Low cut off 10 VDC 20 VDC 30 VDC 40 VDC
  • (b)  UPS output voltage
  • (c)  Wattage of load
  • (d)  Wide input voltage window
  • (e)  Charger on/off
  • (f)  Charging current
  • (g)  Mains charging/Solar charging
  • (h)  UPS on/off
  • (i)  OVER LOAD : If load is above 100 and below 300 percentage
  • (j)  Heavy : If load is above 300 percentage
  • (k)  Short circuit
  • (l)  Over load trip
IMPORTANT SAFETY INSTRUCTIONS
  • (1)  Never push objects of any kind into this UPS through cabinet slots as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock.
  • (2)  Avoid dirty places since accumulated dust inside the chassis may cause failure of the UPS when high humidity persist. Do not use this UPS near water. For example near a bath tub , wash bowl, kitchen sinks or laundry tub or often area, in a wet basement etc.
  • (3)  Never cover the slots and the cooling fan of this UPS with cloth or other material.
  • (4)  Never place the UPS and battery near or over a radiator or heat register.
  • (5)  Never place any type of articles over the UPS and battery.
  • (6)  Never places the ups in a BUILT-IN enclosure.
  • (7)  If a strange sound or smell given UPS, please disconnect mains and battery immediately, then refer to service center.
TECHNICAL SPECIFICATION
Battery input Voltage 12 V, 24 V, 36V, 48V DC
Mains Input:-Wide input range UPS Mode 100 – 300 volt(45 Hz to 65 Hz)

180 – 260 volt(45 Hz to 65 Hz)

Output voltage on Mains Mode Same as Input voltage
Output voltage on UPS Mode 215 +/-5%
Output Frequency 50Hz +/- 0.1Hz
Output Wave form on Mains Mode Same as input
Output Wave form on UPS Mode Pure Sine Wave
Battery charging 8 amps constant current SMPS charging
Charger working range 115 volt to 270 volt 45Hz to 65 Hz
NOTE : Because of a policy of continuous product improvement, the specifications are subject to change without notice.